D-Line SAFE-D30/RED Red Coated Fire Rated Cable Clips For Ceiling Voids & PVC Trunking - Priced Individually Length: 20mm | Width: 23mm
The D-Line SAFE-D30/RED is a red passivated coated steel 18th edition fire-rated U-clip for supporting cables when installed direct-to-surface. Fully certified to satisfy legislative requirements to secure all surface cables in escape routes for all non-domestic installations.
within 1-2 working days
D-Line SAFE-D30/RED Description
The D-Line SAFE-D30/RED is a red passivated coated steel 18th edition fire-rated U-clip for supporting cables when installed direct-to-surface. Fully certified to satisfy legislative requirements to secure all surface cables in escape routes for all non-domestic installations.
Used as a bare cable clip, fixed with a fireproof screw to a wall through a 5.7mm diameter hole. The red finish makes a popular solution for containing red-sheathed fire performance cables direct to surface. The 23mm width is ideal for popular 2 x MICC or FP-cable combinations.
After securing the Safe-D Clips, ideally at 300mm intervals for horizontal installations, or 400mm for vertical, installers simply fold over the thumb-friendly tabs to hold the cables. The combination of the pliable gauge steel & rounded corner features makes U-Clips quick & easy to install.
Prevent cables dropping on escape routes allowing time to evacuate densely populated buildings. Fully tested as capable of supporting cables in temperatures of 970°C for 2 hours.
Fully safety tested and certified to & BS7671 & BS5839 part 1 compliant
D-Line SAFE-D30/RED Features
- D-Line SAFE-D30/RED 18th edition red fire-rated U-clip
- Priced individually for total convenience - only order what you need
- Steel construction
- Non corrosive red passivated coating
- Fully tested as capable of supporting cables in temperatures of 970°C for 2 Hours
- 18th Edition Compliant - prevents cables dropping on escape routes
- For supporting cables when installed direct-to-surface
- Ideal for Ceiling Voids
- 5.7mm diameter pre-drilled hole in base
- Red finish makes a popular solution for containing red-sheathed fire performance
- Suitable for 2 x MICC or FP-cable combinations
- Smooth rounded edges and folding tabs that secure cables
- Thumb friendly
- Melting Point in Excess of 1200°C
- For horizontal cable installations 300mm spacings are recommended
- For vertical cable installations 400mm spacings are recommended
- Compliant with BS7671 and BS5839-1 requirements
- Dimensions: Length: 20mm | Width: 23mm